SeaKnots

B43 Battery Switch Questions coming up during my LIFEPO4 Battery Upgrade Process

My AGM batteries are getting a bit tired and I am swapping them out for 400ah of lithium, 2 - 200ah 'drop in' replacements.

My system has the 3000 watt inverter and Truecharge 40+ shore power charger which the boat came with and  I have verified with the battery manufacturer that these will work with the lithium (they said to set the shore power charger to GEL - WARM to get the right charging characteristics). I have also installed solar a few years back so will need to adjust the charging parameters of the Victron MPPT controller and I am installing a new victron DC to DC charger to protect the alternator.

The question I have is on the battery switches. My thought was that all charging sources would be on the "House" side of the switches so you can turn off battery power to the charge sources if needed. Since I see that mine is wired to have charging sources go to the battery side of the positive and negative switches, I have verified that both my new Victron DC charger and Victron MPPT charger controller have internal fuses, so I am a bit more comfortable installing the charging sources on the battery side of the switches.

However, when I had the negative battery switch in the off position, I tested it with the amp meter and noticed that both sides of the switch where grounded to the battery. It seems some dealer installed ground wires go directly to the battery side of the negative switch which may be inadvertently grounding the entire system. 

So 2 questions to the group:

1) is your charger installed on the "battery" side of the switches?

2) Has any one else experienced the Ground Switch issue described above? Any reason to have anything besides the charging & battery ground wires on the battery side of the switch?

Views: 150

Latest Activity

Matt updated their profile
Sep 17
Robert & Sandy joined SeaKnots's group
Thumbnail

Beneteau Corner

The place for SeaKnots members with an interest in Beneteau
Aug 3
Robert & Sandy posted a discussion

SWITH FOR FORE AND AFT HEADS PUMPS

Our Oceanis 43 was recently serviced and since her return neither of the heads macerators are working. There must be a master switch located on board, trouble is I cannot locate it. Any assistance most welcome.BilgolabandsSee More
Jul 14
Michael Boyle replied to Robert & Sandy's discussion IS SEAKNOTS BENETEAU 40/43 ACTIVE. in the group Beneteau 40 & 43
"Still active and always useful "
Jun 11
Michael Boyle replied to Paul O' Kirwan's discussion Flooding due to Bilge pump Reverse Siphon in the group Beneteau 40 & 43
"Have a 2010 43 and whilst racing recently and well heeled over on port had similar experience. Only in the aft heads and haven’t as yet sorted out where the ingress came from but suspect the shower drain. Never happened before in 15 years with…"
Jun 11
Robert & Sandy added a discussion to the group Beneteau 40 & 43
Thumbnail

IS SEAKNOTS BENETEAU 40/43 ACTIVE.

I note there has been no activity on SeaKnots Beneteau 40/43 since early 2025.Is one of my favourite boating sites still alive and kicking?BilgolabandsSee More
Jun 10
Profile Iconfgdfgdf, phreich, reportotosite and 3 more joined SeaKnots
May 26
phreich liked S/V Compadre's group Cascade Owners Unite
Apr 28
ADVERTISE ON SEAKNOTS CONTACT US AT: 
candrac@sailforwater.com

© 2026   Created by CAN DRAC.   Powered by